Fire-Rated Ceiling Installation

Tested Fire-Resistant Ceiling Systems for Commercial Buildings

Acousti Clad Interiors installs fire-rated ceiling systems for commercial, residential, industrial and public-sector projects. Our systems are designed to help protect the structure, maintain compartmentation and restrict the spread of fire and smoke through a building.

We install complete ceiling constructions in accordance with the project’s fire strategy, technical specification and the relevant manufacturer’s tested system.

Office Ceiling

What Is a Fire-Rated Ceiling?

  • A fire-rated ceiling is a complete construction designed and tested to provide fire resistance for a specified period. Depending on the system and project requirements, this may include protection against fire passing through the ceiling and protection for the floor or structural elements above.

  • The required performance can vary between projects. Fire resistance periods may include 30, 60, 90 or 120 minutes where supported by an appropriate tested or assessed system.

  • A fire-rated ceiling is more than fire-resistant plasterboard alone. Its performance depends on the full system, including:

  • Supporting framework

  • Board type and thickness

  • Number of board layers

  • Fixing type and spacing

  • Insulation, where required

  • Perimeter and junction details

  • Service penetrations and access panels

  • Installation workmanship

  • Every component must be compatible with the specified system to maintain its intended performance.

Reception

Our Fire-Rated Ceiling Services

Our services include:

  • Fire-rated MF ceiling installation

  • Suspended fire-resistant ceilings

  • Direct-fix fire-rated ceiling systems

  • Structural soffit protection

  • Steel beam and structural protection

  • Fire-rated ceiling upgrades

  • Replacement of damaged ceiling systems

  • Fire-rated bulkheads and margins

  • Fire-resistant access-panel installation

  • Perimeter and junction sealing

  • Firestopping around service penetrations

  • Insulation and cavity barrier installation

  • Ceiling inspections and remedial works

  • Plasterboard finishing and preparation for decoration

Protecting Floors and Structural Elements

Fire-rated ceiling systems can be used to protect floor constructions, structural steelwork and the occupied areas above or below a ceiling.

The correct system will depend on the existing structure, the direction of fire exposure, the required fire-resistance period and the supporting test evidence. We review the available drawings and specifications before installation to ensure the proposed construction is appropriate for the project.

commercial-refurbishments-exeter-devon
small-fit-out-contractor-exeter-devon

Get in Touch

Acousti Clad

​

Unit 25, De Havilland Road, Skypark, Clyst Honiton, Exeter, EX5 2GE

Our Certifications:

commercial-refurbishments-exeter-devon
commercial-refurbishments-exeter-devon
commercial-refurbishments-exeter-devon
commercial-refurbishments-exeter-devon
Untitled design.webp

Resgistered Office: 
Unit 1, Alphinbrook Court, Exeter, Devon, EX2 8QR

Privacy Policy

Terms & Conditions 

commercial-refurbishments-exeter-devon
commercial-refurbishments-exeter-devon
commercial-refurbishments-exeter-devon
ESPL-logo.webp
commercial-refurbishments-exeter-devon
commercial-refurbishments-exeter-devon
commercial-refurbishments-exeter-devon
commercial-refurbishments-exeter-devon
commercial-refurbishments-exeter-devon
commercial-refurbishments-exeter-devon
Our Clients

COPYRIGHT ACOUSTICLAD 2024 

bottom of page